Kyoto Women's University Academic Information Repository >
紀要論文(Bulletin Paper) >
生活造形 >
第67号(2022-02-01) >
このアイテムの引用には次の識別子を使用してください:
http://hdl.handle.net/11173/3400
|
タイトル: | 医療従事者用X線防護衣の現状と課題 |
その他のタイトル: | Current State and Issues of Medical X-ray Protective Clothing |
著者: | 熊田, 亜矢子 坂下, 理穂 諸岡, 晴美 河原, 伸雅 Kumada, Ayako Sakashita, Riho Morooka, Harumi Kawahara, Nobumasa |
キーワード: | 医療用 X線防護衣 衣服圧 透湿性 |
発行日: | 2022年2月1日 |
出版者: | 京都女子大学生活造形学科 |
抄録: | This study aims to discuss the current state and issues of X-ray protective clothing for medical workers. First, we analyzed the current state of commercial X-ray protective clothing considering their materials, structures, shapes, dimensions, and mass. Then, we measured the clothing pressure in the region around the shoulder while the protective clothing is worn. Because the protective clothing was extremely heavy and its pattern had a planar structure, considerable measurement location-dependent variation in the clothing pressure was observed. In particular, extremely high clothing pressure was noticed in some regions. Flexural uplifts and buckling deformations on the protective clothing were also observed locally. Furthermore, we measured the moisture permeability and found that the material was impermeable to moisture. Therefore, in addition to the issues mentioned above, X-ray protective clothing may also pose the risk of moisture trapping. |
URI: | http://hdl.handle.net/11173/3400 |
出現コレクション: | 第67号(2022-02-01)
|
このリポジトリに保管されているアイテムは、他に指定されている場合を除き、著作権により保護されています。
|